Low-temperature specific heat capacities of foam glass (Type 150P) have been measured from 79-395K by a precision automated adiabatic calorimeter. Thermal conductivities of the glass foams have been determined from 343-395K with a flat steady-state heat-flow meter. Experimental results have shown that both he specific heat capacities and thermal conductivities of the 150P foam glass increased with temperature.