Theoretical bases for calculating the dynamic strength of tempered sheet glass under test condtions (according too GOST 5727-88) are considered. Methods for calculating the minimum height of a falling ball, dynamic stresses appearing in specimens of tempered glass, and the minimum degree of tempering required for providing a specified dynamic strength of the glass are considered.
Origin
Belarus State Tech Acad Building Materials
Journal Title
Glass & Ceramics 53 5-6 1996 169-171
Sector
Flat glass
Class
F 931